Summary0006844: Access Violation
DescriptionI am able to align my sequences using the Alignment Explorer, using the Muscle Alignment tool. I can save the file. I can then export the file in the MEGA format. However, when I try open this file MEGA main menu I get an "Access Violation" error message.
TagsNo tags attached.
Attach Tags (Separate by ",")
First NameZoe
Last NameMcFarlane
Email2469227M@student.gla.ac.uk
Confirm Email2469227M@student.gla.ac.uk
Attached Files? file icon unaligned.mas (254,998 bytes) 2025-09-26 02:33
? file icon exported.meg (260,766 bytes) 2025-09-26 02:33

- Relationships

-  Notes
(0008090)
gstecher (administrator)
2025-09-26 15:13

Hi Zoe,

I am writing in response to the bug report you recently submitted regarding the MEGA software. The error you encountered is caused by a double-quote character in the alignment in the "Zea Mays" sequence at position 2,745 (see attached). Removing this character before aligning will resolve the error. 

Best regards,
Glen Stecher
Institute for Genomics and Evolutionary Medicine
igem.temple.edu

- Issue History
Date Modified Username Field Change
2025-09-26 02:33 guest New Issue
2025-09-26 02:33 guest File Added: unaligned.mas
2025-09-26 02:33 guest File Added: exported.meg
2025-09-26 15:13 gstecher Note Added: 0008090
2025-09-26 15:13 gstecher Status new => resolved
2025-09-26 15:13 gstecher Resolution open => no change required
2025-09-26 15:13 gstecher Assigned To => gstecher